{"id":1861,"date":"2020-10-16T01:43:22","date_gmt":"2020-10-15T20:13:22","guid":{"rendered":"http:\/\/railsamachar.com\/english\/?p=1861"},"modified":"2020-10-16T11:55:02","modified_gmt":"2020-10-16T06:25:02","slug":"authorisation-given-by-the-crs-without-completion-of-electrification-work","status":"publish","type":"post","link":"https:\/\/railsamachar.com\/english\/?p=1861","title":{"rendered":"Authorisation given by the CRS without completion of electrification work"},"content":{"rendered":"<h4 style=\"text-align: justify;\"><strong><span style=\"color: #0000ff;\">The authorisation was granted in spite of severe shortcomings, state of incompleteness and lack of basic safety features installed in the section<\/span><\/strong><\/h4>\n<p style=\"text-align: justify;\"><span style=\"color: #993300;\"><strong>A vigilance complaint<\/strong> is being sent to the Ministry of Civil Aviation since the Chief Commissioner Railway Safety (CCRS) and his organisation reports to this ministry, and is requested that do not send this complaint to the Ministry of Railways since it is likely to be glossed over due to vested interests.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #0000ff;\">It has also been said that there is nothing technical in this complaint as it is about certifying an incomplete work and deals with irregularities in such certification.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #993300;\">The complaint is to bring the following matter of gross irregularity on the part of a CRS while granting &#8220;authorisation&#8221; for introduction of commercial services after an incomplete inspection of Railway Electrification Work in the Tinpahar-Bonidanga section of Malda Division of Eastern Railway.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #0000ff;\">It can be found that the authorisation was granted in spite of severe shortcomings, state of incompleteness and lack of basic safety features installed.<\/span><\/p>\n<h4 style=\"text-align: justify;\"><span style=\"color: #993300;\"><strong>A sample is given below:<\/strong><\/span><\/h4>\n<p style=\"text-align: justify;\"><span style=\"color: #0000ff;\">i. The speed test and current-collection test was not done at all, an unavoidable and unprecedented lapse. How was the Over Head Equipment (OHE) tested? Was it done only visually, or at low voltages?<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #993300;\">ii. As many as about 110 masts were not even erected. This means that the overhead wires were not in place. Then what was inspected?<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #0000ff;\">iii. As much as 31% distance of the rail line was not even provided with overhead wiring at all, then what was inspected by the CRS?<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #993300;\">iv. ATD (Automatic Tensioning Devices): A very critical safety item was deficient as many as 66 out of 110. Adjustment of ATD was not done at all &#8211; (100% deficiency).<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #0000ff;\">v. Droppering: An unavoidable part of electrical path and safety &#8211; 80% not done.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #993300;\">vi. SED: As many as 1555 balance out of 1607 (97%) not installed.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #0000ff;\">vii. Section Insulator and Isolator: Safety items &#8211; 100% deficient.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #993300;\">viii. Earthing was not done in 90% locations of 6912, a serious safety lapse.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #0000ff;\">ix. SSP and TSS: The main power supply transformers and sectioning equipment &#8211; not installed. Without these the overhead wire would not get the power. Not only are these the most basic supply transformers and sectioning devices, their non-installation meant the work was nowhere near completion.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #993300;\">x. Signal and Telecom Works: These had barely started, a long way from completion.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #0000ff;\">xi. The Electrical and Signal &amp; Telecom Works was not even jointly inspected by the Construction Agency and the User Departments \u2013 a mandatory requirement only after which the section should have been offered for authorisation.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #993300;\">xii. Even earthing of fences, platform sheds and Level Crossing Gates was not done, which is most important for public safety.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #0000ff;\">The list above is only an extract from the authorisation issued for commencement of commercial services.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #993300;\">It can be seen from above, not only was the work incomplete to a large extent, even basic safety installations had not been done on the day of CRS\u2019 inspection.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #0000ff;\">One could ask what he inspected after all \u2013 neither the complete work, nor safety installations, even the charging of the OHE was not done with 25KV.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #993300;\">Even the most basic inspection by the construction agency, the Tower Wagon inspection was not done.<\/span><\/p>\n<p style=\"text-align: justify;\"><em><strong><span style=\"color: #0000ff;\">Just terming the authorisation \u201cconditional\u201d doesn\u2019t make it useful and raises serious doubts on the intentions of the request for CRS\u2019 Inspection, the nature of inspection by the CRS and the validity or sanctity of the authorisation, even a conditional one.<\/span><\/strong><\/em><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #993300;\">It is learnt that, as per request of the complainant, the Ministry of Civil Aviation is inquiring and investigating the above complaint very seriously.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #0000ff;\">It is also learnt that most of the CRS has given authorisation so many incomplete civil and electrification works in the last few years, that also require re-inspection and re-authorisation for the safety of rail and passengers.<\/span><\/p>\n<p style=\"text-align: justify;\"><span><i style=\"color: #993300;\">The officers\u00a0<\/i><span style=\"color: #993300;\"><span style=\"caret-color: #993300;\"><i>knowledgeable about the issue say<\/i><\/span><\/span><i style=\"color: #993300;\">\u00a0that<\/i><strong style=\"color: #993300; font-style: italic;\"> &#8220;the CCRS and CRS have been abusing their immunity from Railways to run a corrupt empire. The Ministry of Civil Aviation, to which they report, doesn\u2019t care about their work as it has more important things to look after. So, practically the CCRS and CRS are running an uncontrolled private enterprise to extract money from contractors and railway officers. There is no appeal against their arbitrary and dishonest ways.&#8221;<\/strong><\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #0000ff;\"><em><strong>Ref: CRS\/NF Circle Letter no. R12046\/03\/2018-19\/BDAG-TPH\/RE\/EC\/1922, dated: 30-03-2019.<\/strong><\/em><\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #993300;\">#ccrs #crs #authorisation #cirtification #ohe #electrification #maldadivision #Tinpahar #Bonidanga #inspection #easternrailway #installation #railway #indianrailways #railminindia\u00a0#pmoindia #pmo\u00a0#ministryofcivilaviation<\/span><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The authorisation was granted in spite of severe shortcomings, state of incompleteness and lack of&#8230;<\/p>\n","protected":false},"author":1,"featured_media":1862,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"koo_publish_custom_meta":false,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_publicize_message":"","jetpack_publicize_feature_enabled":true,"jetpack_social_post_already_shared":false,"jetpack_social_options":{"image_generator_settings":{"template":"highway","enabled":false},"version":2}},"categories":[1],"tags":[],"class_list":["post-1861","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-main-story"],"jetpack_publicize_connections":[],"jetpack_featured_media_url":"https:\/\/i0.wp.com\/railsamachar.com\/english\/wp-content\/uploads\/2020\/10\/CCRS-inspection-DUI-JHL.jpg?fit=850%2C544&ssl=1","jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/railsamachar.com\/english\/index.php?rest_route=\/wp\/v2\/posts\/1861","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/railsamachar.com\/english\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/railsamachar.com\/english\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/railsamachar.com\/english\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/railsamachar.com\/english\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=1861"}],"version-history":[{"count":2,"href":"https:\/\/railsamachar.com\/english\/index.php?rest_route=\/wp\/v2\/posts\/1861\/revisions"}],"predecessor-version":[{"id":1871,"href":"https:\/\/railsamachar.com\/english\/index.php?rest_route=\/wp\/v2\/posts\/1861\/revisions\/1871"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/railsamachar.com\/english\/index.php?rest_route=\/wp\/v2\/media\/1862"}],"wp:attachment":[{"href":"https:\/\/railsamachar.com\/english\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=1861"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/railsamachar.com\/english\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=1861"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/railsamachar.com\/english\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=1861"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}